Skip to main content

Passivhaus Plus terraced house in Vilanova i la Geltrú (Cataluña)

Solar photovoltaic panels on the roof of the building
Case study
Spain

Passivhaus Plus terraced house in Vilanova i la Geltrú (Cataluña)

To reach the Passivhaus Plus certification, 18 solar photovoltaic panels were installed on the roof to produce a 6.7 kWp generator.
Editorial Team

The outer walls of this terraced house are insulated with 100mm of external of EPS thermal insulation, and with 200mm of XPS insulation on the roofs. The house has a balanced mechanical ventilation system with heat and moisture recovery which is certified as a Passivhaus component for warm climates.

Thermal envelope

Exterior wall: 100mm EPS external insulation on honeycomb brick
U-value = 0.253 W/(m2K) 

Basement floor/floor slab: 95mm XOS insulation
U-value = 0.31 W/(m2K) 

Roof: 200mm XPS insulation
U-value = 0.15 W/(m2K) 

Mechanical systems

Ventilation: Balanced whole-house mechanical ventilation with heat and moisture recovery

Heating installation: Air-to-air direct expansion heat pump with indoor ducted split units

Domestic hot water: Air-to-water heat pump 

PHPP values

PE demand (non-renewable Primary Energy): 58 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP 

PER demand (renewable Primary Energy): 36 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP
 

Geographic coverage
Local (city or municipality)
Original Author
Passive House Database
Original source: